Multi-point temperature sensor
W-MP / T-MP(datasheet 21)
Features
- multi-point measurement to a drilled well or a container
- temperature range -200…+1200 °C
- Pt100 or thermocouple (TC)
- standard materials AISI 316L or INCONEL 600, others on request
- available with a connection box fixed to the flange or to be fixed separately
- Pt100, accuracy class A, as a standard, more accurate on request
- TC, class 1 as a standard
- MI-construction, bendable, vibration proof
- tailored solutions according to specific needs
- ATEX-versions, Exi available.
Typical applications
- energy and power plant technology
- process industry
- chemical industry
Drawing 1 – version …BOX-X=CABLED
Drawing 2 – version …BOX-X=FIXED.
Technical data
MI-wire material | AISI, max. temp. +550 °C, temporarily +600 °C. INCONEL 600, max. +1000 °C, temporarily +1200 °C. |
Flange material and type | Material AISI 316L, others on request. Type according to ANSI, EN 1092-1, others on request |
Elements | Made of MI-wire. Outer diameter 3 or 6 mm, others on request |
Connection box | Material stainless steel, others on request |
Cable material | SIL = silicon, max +180 °C FEP = teflon®, max +205 °C GGD = glass silk/metal braid, max +350 °C |
Cable length | According to application |
Tolerances Pt100 (EN-60751) | A, tolerance +/- 0,15 + 0,002 x t, operating temperature -100…+450 °C B, tolerance +/- 0,3 + 0,005 x t, operating temperature -196…+600 °C B 1/3 DIN, tolerance +/- 1/3 x (0,3 + 0,005 x t), operating temperature -196…+600 °C B 1/10 DIN, tolerance +/- 1/10 x (0,3 + 0,005 x t), operating temperature -196…+600 °C |
Tolerances TC (EN-60584-2) | Type J, tolerance class 1 = -40…375 °C +/- 1,5 °C, 375…750 °C +/- 0,004 x t Type K and N, tolerance class 1 = -40…375 °C +/- 1,5 °C, 375…1000 °C +/- 0,004 x t |
Temperature range Pt100 | -200…+550 °C, depending on application and material |
Temperature range TC |
-200…+1200 °C depending on thermocouple type and material TC = thermocouple |
Approvals | GOST-R, METROLOGICAL PATTERN APPROVAL, ROSTECHNADZOR |
Quality certificate | ISO 9001:2008 issued by DNV |
Connections
Pt100 wire colors
TC wire colors, types J, K and N
Download | Format | |
---|---|---|
![]() |
Datasheet-EN-21 |
- + Drawing 1
-
Drawing 1 – version …BOX-X=CABLED
- + Drawing 2
-
Drawing 2 – version …BOX-X=FIXED.
- + Technical data
-
Technical data
MI-wire material AISI, max. temp. +550 °C, temporarily +600 °C.
INCONEL 600, max. +1000 °C, temporarily +1200 °C.Flange material and type Material AISI 316L, others on request.
Type according to ANSI, EN 1092-1, others on requestElements Made of MI-wire. Outer diameter 3 or 6 mm, others on request Connection box Material stainless steel, others on request Cable material SIL = silicon, max +180 °C
FEP = teflon®, max +205 °C
GGD = glass silk/metal braid, max +350 °CCable length According to application Tolerances Pt100 (EN-60751) A, tolerance +/- 0,15 + 0,002 x t, operating temperature -100…+450 °C
B, tolerance +/- 0,3 + 0,005 x t, operating temperature -196…+600 °C
B 1/3 DIN, tolerance +/- 1/3 x (0,3 + 0,005 x t), operating temperature -196…+600 °C
B 1/10 DIN, tolerance +/- 1/10 x (0,3 + 0,005 x t), operating temperature -196…+600 °CTolerances TC (EN-60584-2) Type J, tolerance class 1 = -40…375 °C +/- 1,5 °C, 375…750 °C +/- 0,004 x t
Type K and N, tolerance class 1 = -40…375 °C +/- 1,5 °C, 375…1000 °C +/- 0,004 x tTemperature range Pt100 -200…+550 °C, depending on application and material Temperature range TC
-200…+1200 °C depending on thermocouple type and material TC = thermocouple Approvals GOST-R, METROLOGICAL PATTERN APPROVAL, ROSTECHNADZOR Quality certificate ISO 9001:2008 issued by DNV - + Code Key
- + Connection
-
Connections
Pt100 wire colors
TC wire colors, types J, K and N
- + Download
-