Multi-point temperature sensor

pro-img

Multi-point temperature sensor

W-MP / T-MP(datasheet 21)

Features
  • multi-point measurement to a drilled well or a container
  • temperature range -200…+1200 °C
  • Pt100 or thermocouple (TC)
  • standard materials AISI 316L or INCONEL 600, others on request
  • available with a connection box fixed to the flange or to be fixed separately
  • Pt100, accuracy class A, as a standard, more accurate on request
  • TC, class 1 as a standard
  • MI-construction, bendable, vibration proof
  • tailored solutions according to specific needs
  • ATEX-versions, Exi available.
Typical applications
  • energy and power plant technology
  • process industry
  • chemical industry

Drawing 1 – version …BOX-X=CABLED

Drawing 2 – version …BOX-X=FIXED.

Technical data

MI-wire material AISI, max. temp. +550 °C, temporarily +600 °C.
INCONEL 600, max. +1000 °C, temporarily +1200 °C.
Flange material and type Material AISI 316L, others on request.
Type according to ANSI, EN 1092-1, others on request
Elements Made of MI-wire. Outer diameter 3 or 6 mm, others on request
Connection box Material stainless steel, others on request
Cable material SIL = silicon, max +180 °C
FEP = teflon®, max +205 °C
GGD = glass silk/metal braid, max +350 °C
Cable length According to application
Tolerances Pt100 (EN-60751) A, tolerance +/- 0,15 + 0,002 x t, operating temperature -100…+450 °C
B, tolerance +/- 0,3 + 0,005 x t, operating temperature -196…+600 °C
B 1/3 DIN, tolerance +/- 1/3 x (0,3 + 0,005 x t), operating temperature -196…+600 °C
B 1/10 DIN, tolerance +/- 1/10 x (0,3 + 0,005 x t), operating temperature -196…+600 °C
Tolerances TC (EN-60584-2) Type J, tolerance class 1 = -40…375 °C +/- 1,5 °C, 375…750 °C +/- 0,004 x t
Type K and N, tolerance class 1 = -40…375 °C +/- 1,5 °C, 375…1000 °C +/- 0,004 x t
Temperature range Pt100 -200…+550 °C, depending on application and material
Temperature range TC
-200…+1200 °C depending on thermocouple type and material         TC = thermocouple
Approvals GOST-R, METROLOGICAL PATTERN APPROVAL, ROSTECHNADZOR
Quality certificate ISO 9001:2008 issued by DNV

.


Code key, data sheet 21

Click to open the code key image

Connections

Pt100 wire colors

TC wire colors, types J, K and N

Download Format
Datasheet-EN-21 .pdf
+ Drawing 1

Drawing 1 – version …BOX-X=CABLED

+ Drawing 2

Drawing 2 – version …BOX-X=FIXED.

+ Technical data

Technical data

MI-wire material AISI, max. temp. +550 °C, temporarily +600 °C.
INCONEL 600, max. +1000 °C, temporarily +1200 °C.
Flange material and type Material AISI 316L, others on request.
Type according to ANSI, EN 1092-1, others on request
Elements Made of MI-wire. Outer diameter 3 or 6 mm, others on request
Connection box Material stainless steel, others on request
Cable material SIL = silicon, max +180 °C
FEP = teflon®, max +205 °C
GGD = glass silk/metal braid, max +350 °C
Cable length According to application
Tolerances Pt100 (EN-60751) A, tolerance +/- 0,15 + 0,002 x t, operating temperature -100…+450 °C
B, tolerance +/- 0,3 + 0,005 x t, operating temperature -196…+600 °C
B 1/3 DIN, tolerance +/- 1/3 x (0,3 + 0,005 x t), operating temperature -196…+600 °C
B 1/10 DIN, tolerance +/- 1/10 x (0,3 + 0,005 x t), operating temperature -196…+600 °C
Tolerances TC (EN-60584-2) Type J, tolerance class 1 = -40…375 °C +/- 1,5 °C, 375…750 °C +/- 0,004 x t
Type K and N, tolerance class 1 = -40…375 °C +/- 1,5 °C, 375…1000 °C +/- 0,004 x t
Temperature range Pt100 -200…+550 °C, depending on application and material
Temperature range TC
-200…+1200 °C depending on thermocouple type and material         TC = thermocouple
Approvals GOST-R, METROLOGICAL PATTERN APPROVAL, ROSTECHNADZOR
Quality certificate ISO 9001:2008 issued by DNV
+ Code Key

.


Code key, data sheet 21

Click to open the code key image

+ Connection

Connections

Pt100 wire colors

TC wire colors, types J, K and N

+ Download
Download Format
Datasheet-EN-21 .pdf