Flanged temperature sensor

Flanged temperature sensor

T-F / W-F, according to DIN 43772 (2F datasheet 3)

Features

  • temperature range -200…+1200 °C
  • Pt100 or thermocouple
  • wetted parts material according to the application
  • available also with special coating »
  • Pt100, accuracy class A, as a standard, more accurate on request
  • TC, class 1 as a standard
  • replaceable inner element, MI-construction
  • flange size and type according to the application
  • tailored solutions according to specific needs
  • ATEX-versions, Ex i and Ex d available.

Typical Applications

  • Energy and power plant technology
  • Process industry
  • Chemical industry
  • Machinery, plant and vessel construction.

Drawing

Technical data

 

Thermowell Material AISI, max. temp. +550 °C, temporarily +850 °CHeat-resistant steel 1.4841, max. temp. +1100 °C, temporarily +1250 °C

Available also with special coating »

Flange Type A = flat face (standard), according to DIN EN 1092-1, type 05AType B = raised face, according to DIN EN 1092-1, type 05B

others on request

Tolerances Pt100 (EN-60751) A, tolerance +/- 0,15 + 0,002 x t, operating temperature -100…+450 °CB, tolerance +/- 0,3 + 0,005 x t, operating temperature -196…+600 °C

B 1/3 DIN, tolerance +/- 1/3 x (0,3 + 0,005 x t), operating temperature -196…+600 °C

B 1/10 DIN, tolerance +/- 1/10 x (0,3 + 0,005 x t), operating temperature -196…+600 °C

Tolerances TC (EN-60584-2) Type J, tolerance class 1 = -40…375 °C +/- 1,5 °C, 375…750 °C +/- 0,004 x tType K and N, tolerance class 1 = -40…375 °C +/- 1,5 °C, 375…1000 °C +/- 0,004 x t
Temperature range Pt100 -200…+550 °C
Temperature range TC -200…+1200 °C depending on thermocouple typeHL = 250 mm -> temp. max. +750 °C

HL = 300 mm -> temp. max. +1000 °C                                               TC = thermocouple

HL = 350 mm -> temp. max. +1200 °C                                               HL = cooling neck length = 145 mm as standard

 

Approvals ATEX, GOST-R, METROLOGICAL PATTERN APPROVAL, ROSTECHNADZOR
Quality certificate ISO 9001:2008 issued by DNV
IP-class IP65, higher IP-class on request

Flanged well + Pt100/thermocouple sensing element – example code:

 

csm_2-code_e6648ed14e

Click to open the code key image

Connections

TC type J/K/N wire colors

Installation example

Connection heads

Version D/H with quick release clip and blue epoxy lack finish is our standard, but for certain applications other types are better suited.

Download Format
Datasheet-EN-3 .pdf
+ Drawing

Drawing

+ Technical data

Technical data

 

Thermowell Material AISI, max. temp. +550 °C, temporarily +850 °CHeat-resistant steel 1.4841, max. temp. +1100 °C, temporarily +1250 °C

Available also with special coating »

Flange Type A = flat face (standard), according to DIN EN 1092-1, type 05AType B = raised face, according to DIN EN 1092-1, type 05B

others on request

Tolerances Pt100 (EN-60751) A, tolerance +/- 0,15 + 0,002 x t, operating temperature -100…+450 °CB, tolerance +/- 0,3 + 0,005 x t, operating temperature -196…+600 °C

B 1/3 DIN, tolerance +/- 1/3 x (0,3 + 0,005 x t), operating temperature -196…+600 °C

B 1/10 DIN, tolerance +/- 1/10 x (0,3 + 0,005 x t), operating temperature -196…+600 °C

Tolerances TC (EN-60584-2) Type J, tolerance class 1 = -40…375 °C +/- 1,5 °C, 375…750 °C +/- 0,004 x tType K and N, tolerance class 1 = -40…375 °C +/- 1,5 °C, 375…1000 °C +/- 0,004 x t
Temperature range Pt100 -200…+550 °C
Temperature range TC -200…+1200 °C depending on thermocouple typeHL = 250 mm -> temp. max. +750 °C

HL = 300 mm -> temp. max. +1000 °C                                               TC = thermocouple

HL = 350 mm -> temp. max. +1200 °C                                               HL = cooling neck length = 145 mm as standard

 

Approvals ATEX, GOST-R, METROLOGICAL PATTERN APPROVAL, ROSTECHNADZOR
Quality certificate ISO 9001:2008 issued by DNV
IP-class IP65, higher IP-class on request
+ Code key

Flanged well + Pt100/thermocouple sensing element – example code:

 

csm_2-code_e6648ed14e

Click to open the code key image

+ Connections

Connections

TC type J/K/N wire colors

+ Installation example

Installation example

+ Connection heads

Connection heads

Version D/H with quick release clip and blue epoxy lack finish is our standard, but for certain applications other types are better suited.

+ Downloads
Download Format
Datasheet-EN-3 .pdf